100 kV Large Range CTA
- Stent surgery follow up exam, severe stenosis of celiac trunk.
- CTDIvol: 7.5 mGy , DLP: 542.7 mGy*cm, Effective dose: 8.14 mSv; Scan length: 701 mm
100 kV Abdomen CTA
- Reexamination after aortic dissection stenting.
- CTDIvol: 7.5 mGy, DLP: 536 mGy*cm, Effective dose: 8.04 mSv; Scan length: 692 mm
80 kV Carotid CTA
- Right vertebral artery narrow.
- CTDIvol: 6.4 mGy, DLP: 241.1 mGy*cm, Effective dose: 0.75 mSv
HD Imaging Chain
- Market-leading high definition imaging solutions and innovations are brought together in NCT series, delivering clear visualization of subtle structures, early detection of micro-lesions and exceptional clinical outcomes.
Excellent Clinical Routine
- Narang Medical is continuously innovating state-of-the-art Reconstruction Algorithms for image clarity.
- For neuro imaging, NCT series delivers the speed and accuracy, enabling fast life-saving interveution decisions with detailed display of brain structures.
- For lung imaging, low-dose high definition acquisition enables CT lung cancer screening more accessible to high-risk, asymptomatic individuals.
- For abdomenal imaging, NCT series’s balanced imaging chain offers defined edges and natural contouring for every clinical anatomy and lesions, essentially enhancing diagnostic confidence.
- For orthopedic imaging, fast scan time, long scanning range, consistent image quality with a significant dose reduction benefit are the keys to reliable diagnostic outcomes for trauma patients who are potentially in a lot of pain and require immediate care.
Spectral Imaging
- With the assistance of Spectral Imaging, NCT series allows acquisition of both anatomical and functional information, providing better contrast images, metal artifact reduction, material separation and affirmation of eff-Z number, resulting in major gains in specificity and diagnostic accuracy.
Gout Virtualization
- With an examination set up as simple as a regular spiral scan, Spectral Imaging adds valuable quantitative information to the morphology of conventional CT scans, providing material decomposition that can prove useful for gout visualization.
Metal Artifact Reduction
- Imaging patients with metal implants has long been a challenge for all modalities. NCT series powered by Spectral Imaging can significantly reduce beam hardening artifacts through monochromatic energy synthesis, resulting in outstanding image quality with valuable diagnostic information.
Energy Saving Design
- NCT series utilizes intelligent power management design to optimize power consumption during scanning and reduces stand-by power consumption, in combination with effective electricity transmission system, resulting in 12% power usage reduction. Decreased energy requirements lowers operational costs while minimizing the environmental footprint contributing to a greener planet.
Technical Specifications:
Key data:
- Tube heat capacity…………………………3.5 MHU
- Generator power…………………….……..…32 kW
- kV steps………………………………………………..60, 70, 80, 100, 120, 140 kV
- mA range………………………………………………10-320 mA
- Slices………………………………………………………16 slices
- Rotation time…………………………………..…0.71 s/360°
- Spatial resolution………………………………15 lp/cm @ 0% MTF
- Low contrast resolution…………………2 mm @ 0.3%